0
  • Home
  • Shop
  • About
  • Contact
  • Shop by Clubs
    • Cleaning Kits
    • Biostar Motherboard
    • Gel Pens
    • Large Cushions
    • Bottle Openers
    • Led Lighting
    • Emerald Cut Rings
    • Display Chains
    • Dry Sump
    • Bumpers & Fenders
    • Kb Pistons
    • Contenitori Miele
    • Tp Link
    • High Pressure Washer
    • Tie Ons
    • Fashion Lids
    • Organic Food
    • Wet Dog Food
    • Past Exhibitors
  • Shop by Category
    • Household Essentials
    • Confectionery & Chocolates
    • Cuidado Del Cabello
    • Bathroom Safety
    • Pan Liners
    • Twin Air
    • Home & Living
    • Crochet Beads
LOGIN & REGISTER
0

Currently Empty: ₹0.00

Continue shopping

Follow Us:
Facebook-square X-twitter Instagram
  • Home
  • Shop
  • About
  • Contact
  • Shop by Clubs
    • Filtre À Air
    • Woocommerce Extensions
    • Apparel & Accessories
    • Specialty Items
    • Children S Books
    • Sundance Plumbing
    • Pool Parts
    • Men Sexual Care
    • Dog Apparel
    • Bow Ties
    • Gift Set
    • Claw With Holes
    • Cage Accessories
    • Alfa Romeo
    • Organic Coffee
    • Maple Syrup
    • Jodi King
    • Cutters For Clay
    • Kitchen Tools
  • Shop by Category
    • Inlets & Returns
    • Ceiling Mics
    • Picture Frames
    • Pet Apparel
    • Toys & Hobbies
    • Balboa Circuit Boards
    • Knitting Needles
    • Rosé Wine

WHAT ARE YOU LOOKING FOR?

Login

Remember me Lost your password?
No account yet? Create an account

Register

A password will be sent to your email address.

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our Balboa BP501G1 Spa Circuit Board — G1351 (56944-01) — Multi-Setup 240V Control System.

Have an Account. Login
0

Your Cart

Currently Empty: ₹0.00

Continue shopping

0
  1. Home
  2. Healthy Back Bag
  3. Round Rugs
  4. Balboa BP501G1 Spa Circuit Board — G1351 (56944-01) — Multi-Setup 240V Control System
    On Sale!
    ��️ Balboa BP501G1 Spa Circuit Board — G1351 (56944-01) — Multi-Setup 240V Control System Professional-grade replacement circuit board for reliable two-pump or circ-pump spa control. �� Product Overview The Balboa BP501G1 spa circuit board (G1351, formerly 56944-01) is a genuine Balboa Water Group OEM PCB designed for the BP501G1 control system platform. This is one of Balboa’s most versatile and widely deployed circuit boards, capable of operating across six software-selectable setup configurations covering two-pump, blower, circulation pump, and single-pump spa arrangements. The BP501G1 PCB manages up to two pumps, a blower, a circulation pump, spa lighting, an ozone generator, and an auxiliary/audio-video output — all configurable via DIP switches and jumpers to match a broad range of original equipment builds. It is compatible with the full range of Balboa TP-series and spaTouch™ touchscreen topside panels. This board is a direct replacement for legacy Balboa BP501G1 system boards including part numbers 56488, 56488-02, and 56944-01. It is used across numerous hot tub brands including Cal Spas and Platinum Spas. Ships in factory default Setup #1; setup number, DIP switches, and voltage-select jumpers must be adjusted to match your existing board configuration before installation. ⚠️ Critical Limitation: A circulation pump cannot be used together with a 2-speed Pump 1 on this board. If your spa runs a 2-speed Pump 1 AND a circ pump simultaneously, the BP501G2 is required instead. �� Key Features ✅ Genuine Balboa Water Group OEM PCB — Factory-quality board with chip BP501-X; not an aftermarket substitute ✅ Six Software Setups — Field-selectable configurations cover 2-speed pump, single-speed pump, circ pump, Pump 2, and blower combinations to match diverse original spa builds ✅ Dual-Pump Capability — Controls Pump 1 (2-speed or 1-speed) plus Pump 2 (1-speed) in Setups 1 & 2 ✅ Blower Output — Dedicated 240V blower output (4A max) available in Setups 3 & 4 ✅ Circulation Pump Support — Built-in circ pump output (2A max) with programmable filtration and polling cycles in Setups 2, 4, and 6 ✅ 5.5kW or 4.0kW Heater Compatible — Supports both heater capacities depending on system part number ✅ Ozone Output — 240V ozone output slaved to heater pump (circ or P1 Low) for effective water treatment ✅ Broad Topside Compatibility — Works with Balboa TP200, TP400, TP500, TP600, TP700, TP740, TP800, TP900, and all spaTouch™ panel series ✅ AV / Clim8zone™ Output — Integrated 240V output for audio-video accessories and Clim8zone™ heat pump support (J47) ✅ CHROMAZON3™ Compatible — Supports Balboa’s LED color lighting system (shared 2A light output) ✅ bba™2 / bba™3 Bluetooth Amp Ready — Balboa Bluetooth module compatible via integrated TP700/TP800/TP900/spaTouch™ panels ✅ 1-Year Manufacturer Warranty — Backed by Balboa Water Group ✅ Made in the USA — Balboa Water Group, a Helios Technologies company �� Technical Specifications Specification Value Current Balboa Part Number (MPN) G1351 Previous Part Number 56944-01 Legacy Part Number 56488 / 56488-02 Main PCBA Part Number 56944-02 Chip Number BP501-X Board Model BP501G1 Connector Type 4-pin Molex Board Dimensions 11 in × 5 in System PNs (5.5kW variants) 56485-07 (800 Incoloy), 56486-07 (825 Incoloy), 56487-07 (Titanium) System PN (4.0kW variant) 56567-06 (800 Incoloy) UL System Model (5.5kW) BP501-BP501G1-BU UL System Model (4.0kW) BP501-BP501G1-BS Software Version V65.0 (M100_201) Input Voltage (standard) 240VAC / 50/60Hz Service (standard 240V) 48A, Class A GFCI-protected, 4-wire (Hot, Hot, Neutral, Ground) Max Breaker (standard 240V) 60A Input Voltage (Setups 5 & 6 only) 120V or 240VAC / 50/60Hz Service (120V, wall-mount GFCI) 16A, 20A GFCI/breaker Service (120V, GFCI cord) 12A max Max Breaker (120V) 20A Pump 1 Output 240VAC, 2-Speed (Setups 1,3,5) or 1-Speed (Setups 2,4,6), 12A max Pump 2 Output 240VAC, 1-Speed, 12A max — Setups 1 & 2 Blower Output 240VAC, 1-Speed, 4A max — Setups 3 & 4 Circ Pump Output 240VAC, 1-Speed, 2A max — Setups 2, 4, 6 Ozone Output 240VAC, 0.5A max Spa Light Output 10VAC, 2A max (shared with CHROMAZON3™) AV / Clim8zone™ Output (J47) 240VAC, 2A (AV) 8A (C8Z) max Heater Output (5.5kW systems) 5.5kW @ 240VAC Heater Output (4.0kW systems) 4.0kW @ 240VAC Heater Output (120V, Setups 5 & 6) 1.25kW @ 120VAC Number of Software Setups 6 DIP Switches 6-position Switchbank S1 Fuse F3 10A 250V (PN 26904) Fuse F4 2A 250V (PN 26307) Fuse F5 30A 250V (PN 30136) Fuse F6 0.5A 250V (PN 26905) Fuse F7 2A 250V (PN 26307) Wire Type Copper conductors only Minimum Wire Gauge #6 AWG, 90°C-rated TB1 Torque 27–30 in. lbs. Heater Connection Torque 30–35 in. lbs. Hi-Range Temp (adjustable) 80°F–104°F (26.7°C–40°C) Lo-Range Temp (adjustable) 50°F–99°F (10°C–37.2°C) Freeze Threshold 44°F (6.7°C) Warranty 1 year (manufacturer) ⚠️ Board ships in factory default Setup #1. Setup number, DIP switches, and voltage-select jumpers must be adjusted to match your original board’s configuration prior to installation. ℹ️ US Voltage Note: Standard residential 240V/60Hz service. Setups 5 & 6 only support optional 120V operation with appropriate GFCI protection. ✅ Compatibility Guide Compatible Topside Panels: Panel Series Version Required Notes spaTouch™ Mini Any Any version for Clim8zone™ support (v1.0 ) spaTouch™ 3 Any v3.2 for Clim8zone™ support spaTouch™ 2 Any v2.19 for CHROMAZON3™; v2.36 for Clim8zone™ Icon spaTouch™ Any v3.36 for bba™2 fully integrated Menued spaTouch™ Any v2.8 for bba™2 integrated TP900 v3.1 and later v3.13 for bba™ TP800 v3.1 and later v3.13 for bba™; v4.11 for bba™2 integrated TP700 / TP740 Any v1.27 for Clim8zone™ support TP600 v2.7 and later v2.12 for bba™/bba™2 On/Off via menu TP500 Any All versions TP400T US v2.7 and later v2.12 for bba™/bba™2 On/Off via menu TP400W US v2.7 and later v2.12 for bba™/bba™2 On/Off via menu TP200T Any All versions TP200W Any All versions Replaces the Following Part Numbers: Legacy Part Number Description 56944-01 Balboa BP501G1 PCB (previous version) 56488 Balboa BP501G1 PCB (legacy) 56488-02 Balboa BP501G1 PCB (legacy) 56485-03 through 56485-07 BP501G1 System, 5.5kW 800 Incoloy (various revisions) 56486-03 through 56486-07 BP501G1 System, 5.5kW 825 Incoloy (various revisions) 56487-03 through 56487-07 BP501G1 System, 5.5kW Titanium (various revisions) 56567-01 through 56567-06 BP501G1 System, 4.0kW 800 Incoloy (various revisions) ⚠️ Always verify your existing board’s chip number and part number before ordering. Do not order a circuit board based on appearance — many boards look similar but have different software. ��️ Board Functions & Setup Configurations Software Setup Reference Table: Setup # Circ Pump Pump 1 Pump 2 Blower Temp Scale 1 (default) None 2-Speed 1-Speed None °F 2 Prog. Filtration Polling 1-Speed 1-Speed None °F 3 None 2-Speed None 1-Speed °F 4 Prog. Filtration Polling 1-Speed None 1-Speed °F 5 None 2-Speed None None °F 6 Prog. Filtration Polling 1-Speed None None °F ⚠️ In Setups 1, 3, and 5 (no circ pump), Pump 1 acts as the heater pump. ⚠️ In Setups 2, 4, and 6 (with circ pump), the circ pump acts as the heater pump. Pump Outputs: Output Connector Voltage Max Amps Timer Pump 1 (2-speed) J8 240VAC 12A max 15 min (30 min P1 Low, non-circ) Pump 2 (1-speed) J14 240VAC 12A max 15 min Blower (1-speed) J14 240VAC 4A max 15 min Circ Pump J21 240VAC 2A max Programmable Heater Control: Feature Specification Heater Type Flow-through (Plug Click connection) Max Output (5.5kW system) 5.5kW @ 240VAC Max Output (4.0kW system) 4.0kW @ 240VAC Max Output (120V, Setups 5 & 6) 1.25kW @ 120VAC Heater Connector J46 Hi-Range Set Temp 80°F–104°F Lo-Range Set Temp 50°F–99°F Freeze Threshold 44°F (6.7°C) — rotating pump activation Cooldown (electric heater) 1 minute (DIP Switch 4 OFF) Cooldown (gas heater) 5 minutes (DIP Switch 4 ON) Additional Outputs: Function Connector Rating Notes Ozone J24 240VAC, 0.5A max Slaved to circ pump (circ setups) or P1 Low (non-circ) Spa Light / CHROMAZON3™ J15 10VAC, 2A max (shared) 240-min timer AV Clim8zone™ J47 240VAC, 2A 8A max Splitter PN 22934 if two devices needed Aux Panel Bank 1 J5 — AX10, AX20, AX40 auxiliary panels DIP Switch Functions (Switchbank S1): Switch OFF Position ON Position 1 Test Mode OFF (normal) Test Mode ON — service only 2 No heat with any HS pump/blower Heat with 1 high-speed pump running 3 See Switch 2 Heat with 2 HS pumps (or 1 HS blower) running 4 1-min cooldown (electric heater) 5-min cooldown (gas heater) 5 Special Amperage Rule A Special Amperage Rule B 6 Normal operation Memory Reset (power-up) ⚠️ Switch 6 must be set to OFF upon final installation. Key Jumpers: Jumper Function J44 230V config: center 2 pins; 115V config: left right 2 pins (when neutral wire used) J29 Heater Disable Switch input; if shorted, heater will not run J25, J26, J27 Heater type settings — factory configured, do NOT change J109 GFCI Test/Trip Enable/Disable J30 Do Not Use ⚙️ Installation Requirements ⚠️ IMPORTANT: Installation must be performed by a licensed electrician in full compliance with NEC (National Electrical Code) and all applicable local codes. Pre-Installation Checklist: [ ] Confirm chip number and part number of existing board before ordering [ ] Note your existing software Setup # (written on label inside system lid) [ ] Disconnect all power at the GFCI breaker or disconnect box [ ] Photograph all wiring, connector positions, DIP switch settings, and jumper positions before removal [ ] Allow capacitors to discharge — wait at least 5 minutes after power-off [ ] Disconnect J52 slip terminal (green wires) before any HiPot test [ ] Note: board ships in Setup #1 — DIP switches, voltage-select jumpers, and setup must be adjusted before power-up Electrical Requirements (Standard 240V Configuration): Requirement Specification Supply Voltage 240VAC / 60Hz Service 48A, 4-wire (Hot, Hot, Neutral, Ground) Circuit Breaker 60A maximum GFCI Protection Class A GFCI required — NEC Article 680 Ground & Bonding Equipment grounding and bonding required — NEC Article 680 Dedicated Circuit Required Disconnect Box Required within line of sight of spa, min. 5 ft from inside spa walls (NEC) Wire Type Copper conductors ONLY Min. Wire Gauge #6 AWG, 90°C-rated TB1 Torque 27–30 in. lbs. Heater Connection Torque 30–35 in. lbs. Electrical Requirements (120V Option — Setups 5 & 6 Only): Requirement Specification Supply Voltage 120VAC / 60Hz Service (wall-mount GFCI) 16A, 20A GFCI/breaker Service (GFCI cord) 12A max Pump 1, Circ Pump, Ozone Must be wired to 120VAC — move wires at J50 and J51 to Area 1 (Neutral) DIP Switches 2 & 3 Must be set to OFF when system is configured for 120VAC Clim8zone™ Cannot be used in 120VAC configuration Key Board Connectors: Connector Function TB1 Main power terminal block J8 Pump 1 (2-speed or 1-speed) J14 Pump 2 (1-speed) or Blower J15 Spa Light / CHROMAZON3™ (10V) J21 Circ Pump J24 Ozone J46 Heater (240V, Plug Click) J47 AV Clim8zone™ J50, J51 P1 / Circ / Ozone voltage selection J5 Aux Panel connection (Bank 1) J33 / J45 Main topside panel connections J52 Disconnect before HiPot test S1 6-position DIP switchbank �� Tip: Using a permanent marker, write the Setup number on the label inside the system lid. This is critical information for any future service technician. Setup Change Procedure (TP600/TP400 Panels): Enter Test Mode: turn DIP Switch 1 ON while system is running During Priming Mode, press any Temperature button once to exit Priming Mode Press: Warm, Light, Warm, Warm, Warm, Warm — continue pressing Warm until desired Setup Number appears Press Light once to confirm — system resets to new Setup Turn DIP Switch 1 OFF to exit Test Mode Memory Reset Procedure: Set DIP Switch 6 to ON at power-up to restore factory settings ⚠️ Switch 6 must be returned to OFF upon final installation ��️ Safety Warnings Electrical Safety: ⚠️ ALWAYS disconnect all power before performing any board work — high-voltage shock hazard ⚠️ Licensed electrician installation required — NEC compliance mandatory ⚠️ Class A GFCI protection required per NEC Article 680 ⚠️ Equipment grounding AND bonding mandatory per NEC Article 680 ⚠️ Verify supply voltage matches board configuration before connecting ⚠️ Use copper conductors only — minimum #6 AWG, 90°C-rated ⚠️ Do not exceed TB1 torque (27–30 in.lbs.) or heater connection torque (30–35 in.lbs.) ⚠️ Disconnect J52 slip terminal (green wires) before performing any HiPot testing DIP Switch & Configuration Safety: ⚠️ Setting DIP switches or jumpers incorrectly may cause abnormal system behavior or component damage ⚠️ Switch 6 (Memory Reset) must be OFF upon final installation ⚠️ Do NOT change factory-configured jumpers J25, J26, J27 (heater type settings) ⚠️ In 120VAC configuration (Setups 5 & 6 only), Pump 1, Circ, and Ozone must all be wired to 120VAC — move J50 and J51 to Area 1 (Neutral) ⚠️ DIP Switches 2 & 3 must be OFF when configured for 120VAC Critical System Limitation: ⚠️ A circulation pump cannot be used together with a 2-speed Pump 1 in this system. If your spa requires this combination, the BP501G2 board is required. Water & Component Safety: ⚠️ Inspect all enclosure seals before installation — no water ingress permitted ⚠️ Never handle electrical components with wet hands ⚠️ Test Mode (DIP Switch 1 ON) exposes high voltage — for licensed service technicians only Post-Installation: ⚠️ Verify all safety features before spa use ⚠️ Test GFCI operation after installation ⚠️ Check for error codes and monitor board on first startup �� Error Codes & Diagnostics Power-Up Sequence: On startup, the spa enters Priming Mode automatically. The display will show “RUN PMPS PURG AIR” during pump purge. Priming Mode exits automatically after 4 minutes, or can be manually exited by pressing a Temperature button. Test Mode Indicators: Display Meaning °T after temperature (e.g., “100T”) System is in Test Mode (DIP Switch 1 ON) “°F” or “°C” after temperature Normal operating mode “J29” on display at power-up J29 heater disable connector is shorted — check for external switch closure or short at J29 “S-01”, “S-02” etc. Software Setup selection screen (during Test Mode setup change) Fault Log: Accessible via the Test Menu on TP800/TP900/spaTouch™ panels. Records system faults for service diagnosis. Filter Reminders (default schedule): Reminder Default Period Clean Filter 30 days Test GFCI 65 days Drain Water 100 days Change Filter 365 days ⚠️ For complete BP501 error code documentation, refer to the Balboa BP501G1 Tech Sheet (see Downloads) or contact Parts4Tubs technical support. �� Ideal Applications Application Suitability Notes ♨️ Two-pump spas (P1 P2, no circ) ✅ Setup 1 — direct application P1 is heater pump ♨️ Two-pump spas (P1 P2, with circ) ✅ Setup 2 — circ as heater pump Circ pump required ♨️ Single-pump blower spas ✅ Setups 3 & 4 With or without circ ♨️ Single-pump only spas ✅ Setups 5 & 6 Optional 120V operation ♨️ Cal Spas (BP501G1 equipped) ✅ Compatible OEM board for select Cal Spas models ♨️ Platinum Spas ✅ Compatible Replaces CTR-BP501G1 ♨️ Any BP501G1 system spa ✅ Direct PCB replacement Confirm setup, chip number This board is NOT suitable for: Spas requiring a 2-speed Pump 1 combined with a circ pump simultaneously — use BP501G2 instead Export 50Hz CE-market spas — this is a UL/North American 60Hz board ❓ Frequently Asked Questions Q: How do I know which Setup my spa uses? A: Check the label inside your system enclosure lid — the Setup number should be written there. If not, check the wiring diagram attached to the inside of the spa pack cover, or contact Parts4Tubs with your spa make, model, and control system part number. Q: My spa has a 2-speed pump and a circ pump. Will this board work? A: No. The BP501G1 cannot run a 2-speed Pump 1 together with a circulation pump. Your spa requires the BP501G2 instead. Contact Parts4Tubs for assistance. Q: Is this an OEM or aftermarket board? A: This is a genuine Balboa Water Group OEM circuit board (G1351 / 56944-01). Q: The board ships in Setup #1 — do I need to change it? A: Yes, if your original board was configured in a different Setup. You must adjust the Setup number, DIP switches, and voltage-select jumpers to match your original board’s configuration. Refer to the tech sheet and wiring diagram inside your spa pack cover. If you are unsure, contact Parts4Tubs for assistance. Q: Can this board run on 120V? A: Yes, but only in Setup 5 or Setup 6, and only with appropriate 120V GFCI protection. In 120V mode, the heater outputs 1.25kW. Pump 1, circ pump, and ozone must all be rewired to 120VAC (J50 and J51 to Area 1). DIP Switches 2 and 3 must be OFF. Note that Clim8zone™ cannot be used in 120VAC configuration. Q: Do I need a licensed electrician to install this? A: Yes. NEC Article 680 and most local codes require a licensed electrician for all hot tub electrical work. A permit may also be required in your jurisdiction. Q: Which topside panel works with this board? A: The BP501G1 is compatible with a wide range of Balboa panels including TP200, TP400, TP500, TP600, TP700, TP740, TP800, TP900, and the full spaTouch™ line. See the Compatibility Guide section for version requirements. Contact Parts4Tubs if you are unsure about your specific panel. Q: What warranty is included? A: 1-year manufacturer warranty from Balboa Water Group. Contact Parts4Tubs for complete terms. Q: What if the heater won’t run after installation? A: Check that J29 is not shorted — a shorted J29 disables the heater. If “J29” appears on the display at startup, inspect the heater disable connector. Also verify DIP switch settings and ensure Switch 6 is in the OFF position. �� Downloads & Resources �� Balboa BP501G1 Tech Sheet — Current Version (Official PDF) — Full wiring diagrams, DIP switch settings, setup table, connector layout, panel configurations, and configuration options ⭐ Why Choose the Balboa BP501G1 PCB (G1351) ✅ Genuine OEM Balboa Water Group board — same component as original equipment; no compatibility guesswork ✅ Six field-selectable software setups — one board covers a broad range of pump and blower configurations ✅ Broadest topside panel compatibility — works with all Balboa TP and spaTouch™ panel families ✅ 5.5kW and 4.0kW heater variants available — select the right capacity for your system ✅ Advanced feature support — CHROMAZON3™, bba™2/bba™3 Bluetooth, Clim8zone™ heat pump ready ✅ 1-year manufacturer warranty — factory-backed coverage ✅ Parts4Tubs expert support — our team can help verify your setup configuration and confirm compatibility ✅ Made in the USA — Balboa Water Group, a Helios Technologies company �� Why Buy from Parts4Tubs ✅ Fast US shipping ✅ Expert technical advice from spa specialists ✅ Competitive pricing ✅ Full warranty support ✅ Easy returns within 30 days ✅ Compatible parts and accessories available ✅ Help identifying the correct Setup, DIP switch configuration, and compatible topside panels �� Summary The Balboa BP501G1 PCB (G1351) is a genuine OEM replacement circuit board for the BP501G1 control system platform. With six software-selectable setup configurations, it covers two-pump, blower, circulation pump, and single-pump spa arrangements operating on 240V (or 120V in Setups 5 & 6). It supports heaters up to 5.5kW and is compatible with every Balboa TP-series and spaTouch™ topside panel. If your spa runs a 2-speed Pump 1 without a circ pump, or a 1-speed Pump 1 with a circ pump, this board is the right choice — order with confidence and restore your spa to full operation. Parts4Tubs is proud to be a Balboa Authorized Online Seller - make sure you only buy genuine Balboa parts from trusted sources. Finding and identifying a replacement Hot Tub Circuit Board (PCB) If you are looking to replace a failed PCB on your Hot Tub’s spa pack, then quite often identifying the part that you need can be the hardest thing. Firstly, you are looking for a model number on the actual circuit board itself. Having the model or serial of your hot tub is not going to help at this point, you need to find the number on the PCB itself. Now, with certain brands of PCB, the number of the replacement PCB that you need is not going to match identically the one you are replacing. Why is that I hear you ask? Well, normally, it is an updated version. This means that it might have updated firmware on the PCB or be a later revision. Normally, this means that the part number would be slightly different. This is usually indicated with a “12345678 -x” at the end of that part number where x indicated a firmware revision. In some cases, there will be some following letters on the part number of the circuit board, “12345678 -x MAS” this can indicate that the PCB was used for an OEM meaning it was produced for a certain hot tub manufacturer and the letters identify the manufacturer. This means if you source an original PCB, it will not have the letters, but will in most cases work just fine. It can be confusing I know! What if you can’t find a model number? If you can’t find a model number on the PCB itself, then you need to look for a model number on the spa pack. Normally, there is a sticker on the outside of the spa pack that tells you the current ratings and input voltages etc and this will have a model number. In general, most spa packs in the USA are manufactured by Balboa, Hydro-Quip, ACC or Gecko. I know I am generalising here, but if you have a spa pack that has the brand of your hot tub on, it will be an OEM so the key is identifying who made the original box. From there, you can normally find an original PCB that you will be able to switch out. For example, the Balboa VS (value series) is a very popular spa pack that has been used by multiple hot tub manufacturers under their own brand names. Whatever they have called it, strip it back and it is still a Balboa VS. Visual Inspection One of the most important things you can do when you are looking for a replacement is to visually inspect the PCB that you have versus the picture online of the replacement you are considering. They need to look the same even if there are the differences in firmware revisions or OEM part numbers, you should be visually replacing a PCB that looks like the one you have. Configuring a replacement Hot Tub Circuit Board (PCB) When you get a new PCB, you are more than likely going to need to configure it. Most PCBs have a number of different modes and setups that the can operate in. For this, you will need to manual or spec sheet to guide you. For things like DIP switches, most of the time you can copy the settings from your original circuit board. You are looking for things like setting the voltage as a lot of PCBs can be configured to run on both 115V and 230V. You may need to move jumpers or even wires to configure voltages – the key here is that you read the schematic and don’t expect the PCB to just work out of the box – it usually doesn’t. Troubleshooting a Hot Tub Circuit Board (PCB) Here are some common things you will see when you replace a PCB on a hot tub. You press the buttons on the topside control and they don’t control the right parts (pumps or blower etc) – this is a mode configuration thing and you will either need to change some DIP switches on the PCB or an internal or low level programming mode on the topside control. Check the manual for how to do this. You turn on the hot tub and it trips the breaker – it is not common for a new PCB to fail out of the box (I have not seen one yet!) However, a common mistake is that the voltage has not been set correctly. If it is set for 115V and then you try and turn it on, the current draw will be a lot more (twice) than expected and the breaker will trip. To check this, unplug all of your kit – heater, pumps, blower and then turn on the PCB. If it trips with nothing plugged in, usually the voltage is incorrectly set and what is happening is that live current is being sent to the ground – because you have 4 wires into the PCB rather than 3. Current on the ground loop causes the trip. Check the settings to make sure it is configures for 230V. It might not trip until you physically turn on a pump or a blower. As mentioned, if the pack is set to 115V and your pump is meant for 230V, it will draw twice the current at half the voltage and trip your breaker. Check the manual for info on how to set the voltage.